MCCB 4POLE

    Category: MCCB
  • Brand: Schneider
  • Minimum quantity: 1
  • Price: ₹ 4050


EasyPact CVS100BS is a 4 poles 3d fixed circuit breaker with a high level of performance and cost-saving functionality. It is an optimal choice for small and medium-sized buildings protection applications. The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz.



RangeEasyPact
Range of productEasyPact CVS100...160
Product nameEasyPact CVS
Device short nameCVS100BS
Product or component typeCircuit breaker
Device applicationDistribution
Poles description4P
Protected poles description3D
Earth leakage protection (Vigi add on)Without
[In] rated current100 A at 40 °C
Network typeAC
Suitability for isolationYes
Utilisation categoryCategory A
[Icu] Breaking capacity25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 200/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/400 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating100 A at 40 °C
Protection typeOverload protection (long time)
Instantaneous short-circuit protection


 

RangeEasyPact
Range of productEasyPact CVS100...160
Product nameEasyPact CVS
Device short nameCVS100BS
Product or component typeCircuit breaker
Device applicationDistribution
Poles description4P
Protected poles description3D
Earth leakage protection (Vigi add on)Without
[In] rated current100 A at 40 °C
Network typeAC
Suitability for isolationYes
Utilisation categoryCategory A
[Icu] Breaking capacity25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 200/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/400 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating100 A at 40 °C
Protection typeOverload protection (long time)
Instantaneous short-circuit protection
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Breaking capacity codeBS
[Ics] rated service breaking capacity25 kA at 200/240 V AC 50/60 Hz conforming to IEC 60947-2
17 kA at 380/400 V AC 50/60 Hz conforming to IEC 60947-2
Neutral positionLeft
Mechanical durability13000 cycles
Electrical durability4000 cycles 415 V In conforming to IEC 60947-2
Control typeToggle
Thermal protection adjustment range70…100 A
Neutral protection settingNo protection (3D)
Long time pick-up adjustment type IrAdjustable
Long time pick-up adjustment range0.7...1 x In
Long time delay adjustment typeFixed
Instantaneous pick-up adjustment type IiFixed
Instantaneous pick-up adjustment range800 A
Contact position indicatorYes
Mounting supportBackplate
Mounting modeFixed
Upside connectionFront
Downside connectionFront
Connections - terminalsScrew connection
Connection pitch35 mm
Compatibility codeCVS100
Width100 mm
Depth60 mm
Height130 mm
Net weight1 kg


 

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.0 cm
Package 1 Width10.5 cm
Package 1 Length14.0 cm
Package 1 Weight1.052 kg
Unit Type of Package 2S02
Number of Units in Package 29
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight9.87 kg
Unit Type of Package 3P12
Number of Units in Package 3288
Package 3 Height100 cm
Package 3 Width125 cm
Package 3 Length55 cm
Package 3 Weight327.4 kg